77
Coding in the delivered condition
Possible change
62:15
65:0
No diverter valve
67:40
For solar DHW heating:
Set DHW temperature
40 °C. Reheating is sup-
pressed above the selec-
ted set temperature.
67:0
to
67:95
Set DHW temperature
adjustable from 0 to 95 °C
(limited by boiler-specific
parameters)
6F:...
Maximum output for
DHW heating in %, speci-
fied by the boiler coding
card
6F:0
to
6F:100
Max. output for DHW heat-
ing adjustable from min.
output to 100 %
71:0
DHW circulation pump:
"On" according to time
program
71:1
"Off" during DHW heating
to the first set value
71:2
"On" during DHW heating
to the first set value
72:0
DHW circulation pump:
"On" according to time
program
72:1
"Off" during DHW heating
to the second set value
72:2
"On" during DHW heating
to the second set value
73:0
DHW circulation pump:
"On" according to time
program
73:1
to
73:6
"On" from once per hour for
5 min up to 6 times per hour
for 5 min during the time
program
73:7
Constantly "On"
Solar
Note
The solar group is only displayed if a solar control module, type SM1, is connected.
Code 2
DHW
(cont.)
5692 860 GB