4.
Clock adjust:
hour, minute flash, press K2, K3 modify the data, press K4 to save it.
System checking:
at any time, press K3+K4, it will check and display the related data automatically. Details as in PICTURE 4. If there is
NO, means there is no connection. If the connections are correct, the related data will be displayed. If no remote temperature sensor is
connected, the meter will show thermometer and NO. If connection is correct, it will show the data it detects.
OPEN
means no battery
connection or over voltage, the data will be displayed while the connection is right.
Data erase to 0
: at any time, press K1+K2
,
the data will be erased to 0, such as max, min, Ah. AH accumulate from 0.
OTHER INSTRUCTION:
Specifications:
Rated voltage
:
12V, min voltage (suggest): 8.0V.
Strong backlight on
: <23mA,
Low backlight on
: <20mA
Backlight and LED indicator off
: <17mA
Operation temperature
:
-40
℃
~ +60
℃
LCD operation temperature
: -10
℃
~ +40
℃
Humidity
:
0-100%
Communication cable
:
RJ45(8PIN), 10 meter.
Trouble indicator on
: following occasion may occur, check the connection. And the symbol will disappear automatically when it
resumes.
1.
While one battery disconnect, or open circuit, or over voltage.
2.
The remote temperature sensor is no probe.
3.
Over charging current
4.
Solar PV short-circuits.
Telecommunication port:
while the meter run by individual power or the communication cut off, it displays 4 pieces of “_”. Press key, no
answer. The display will resume while communications is on.
Note: the data displayed got from the communication, check if the cable correct while the data is error, or if there is strong interference.
A too long cable may bring errors too. The data will update every 20 seconds.
Battery capacity strip flash
: each strip equals 20% of battery capacity. The over part will be shown as flashing. For example, the first
trip flash, the battery capacity is 1-19%, the second trip flash, it is 21-39%, etc.
Note: the calculation takes fully charged voltage as 100%, and over discharged as 0%. All is based on battery voltage, not the real battery
capacity.
Battery capacity AH
: AH is the accumulation of charging, each one minute will count. The data is not accurate while the charge current
is too small. The min. is 1AH, means 1amps charging for 1 hour, AH comes to show.
(all rights reserved )
Summary of Contents for BlueSolar SCC010005000
Page 1: ...Manual BlueSolar Charge controller 12 24V 10A with timer ...
Page 45: ...6 MECHANICAL DRAWING ...
Page 51: ...9 MECHANICAL DRAWING ...
Page 52: ...Manual BlueSolar DUO Charger 12V 24V 20A ...
Page 57: ...6 MECHANICAL DRAWING ...
Page 59: ...Manual BlueSolar PWM Charge Controller LCD USB 12V 24V 5A 12V 24V 10A 12V 24V 20A ...
Page 68: ...Manual BlueSolar PWM Light 48V Charge Controller with light turn off timer ...
Page 83: ...Blue Solar PWM Pro setup and monitoring software Manual ...
Page 89: ...5 7 After logging in the following screen will appear ...
Page 102: ...Manual Meter for BlueSolar DUO 12 24V 20A For RVs Caravans and boats ...
Page 114: ......
Page 121: ...8 Dimensions ...