5.10 Failure Information
Displays failures such as Over Voltage, Over Load or Short Circuit.
(automatic reset when the fault is corrected).
5.11 Parameters
The first screen displays the type, software version and serial number
of the remote meter.
The second screen allows modification of
•
Switch-Pages (refresh time interval of the monitoring pages,
default 0 seconds)
•
Backlight duration (default 20 seconds).
•
Audible alarm ON/OFF (default OFF).
6 Technical Specifications
Self-consumption
backlight and acoustic alarm on max. 65mA
Backlight on max. 23mA
Backlight off max. 15mA
Faceplate dimensions 98 × 98 mm / 3.86 × 3.86 inch
Frame dimensions
114 × 114 mm / 4.49 × 4.49 inch
Connector type
RJ45
Cable length
Max. 20 m
Weight
0.2 Kg
Ambient Temperature
-20°C~+70°C / -4°F~158°F
7 RS-485 connector pinout:
Pin No.
1
Power: +12V
2
RS485 B
3
RS485 A
4
GND
5
GND
6
RS485 A
7
RS485 B
8
Power: +12V
Summary of Contents for BlueSolar SCC010005000
Page 1: ...Manual BlueSolar Charge controller 12 24V 10A with timer ...
Page 45: ...6 MECHANICAL DRAWING ...
Page 51: ...9 MECHANICAL DRAWING ...
Page 52: ...Manual BlueSolar DUO Charger 12V 24V 20A ...
Page 57: ...6 MECHANICAL DRAWING ...
Page 59: ...Manual BlueSolar PWM Charge Controller LCD USB 12V 24V 5A 12V 24V 10A 12V 24V 20A ...
Page 68: ...Manual BlueSolar PWM Light 48V Charge Controller with light turn off timer ...
Page 83: ...Blue Solar PWM Pro setup and monitoring software Manual ...
Page 89: ...5 7 After logging in the following screen will appear ...
Page 102: ...Manual Meter for BlueSolar DUO 12 24V 20A For RVs Caravans and boats ...
Page 114: ......
Page 121: ...8 Dimensions ...