22
VE272SFS Roll Grooving Tool
11a.
If a short length of pipe/tubing is in the
tool, manually support the pipe/tubing.
12.
To release the pipe/tubing, open the
hand pump valve by turning the knob
coun-
terclockwise
. Remove the pipe/tubing from
the tool.
NOTICE
• The groove diameter must be within specification
for the diameter and wall thickness of pipe/tubing.
The groove diameter should be checked and
adjusted, as necessary, to ensure grooves remain
within specification.
TM-VE272SFS 3776 Rev_B.fm Page 22 Friday, December 3, 2004 12:10 PM