6.
After every 40 hours of operation, clean
and lubricate the
3
/
4
-inch lower roll (if
equipped) and the 1 – 1
1
/
2
-inch lower roll.
7.
Remove the cap screws, and disassem-
ble the two-piece collar. Remove both the
collar and the needle bearing, along with the
washers.
8.
Remove the lower roll from the arbor.
Clean the
3
/
4
-inch lower roll (if equipped) and
the 1 – 1
1
/
2
-inch lower roll. Lightly lubricate the
lower rolls with dry graphite spray (supplied
with the tool and available from the Victaulic
Tool Company).
9.
Re-assemble the
3
/
4
-inch lower roll (if
equipped) and the 1 – 1
1
/
2
-inch lower roll.
Lubricate the needle bearing with bearing
grease. Make sure the end gaps are uniform
on the two-piece collar.
CHECKING AND FILLING
HYDRAULIC SYSTEMS
The hydraulic fluid level in the hand pump
must be checked semi-annually or if the
pump feels “spongy.”
1.
Open the hand pump valve by turning
the knob
counterclockwise
.
2.
Remove the hand pump/pump support
from the tool base.
3.
Loosen, but do not remove, the hydraulic
fill plug/dipstick at the back end of the pump.