9
XX207-00-02 Rev 910 MP-980DN Camera
IEEE 802.1x, CoS, QoS/DSCP
-
(Advanced Mode) These are not applicable for ViconNet.
HTTP (Advanced Mode)
To utilize HTTP authentication, be sure a password is set first.
“Authentication”-
It supports basic and digest modes, depending on network security requirements.
In basic mode, the password is sent in plain text; digest mode encrypts the password, providing
higher security.
“HTTP port”-
This can be other than the default Port 80; any port between 1025 and 65535 can be
selected. Once the port is changed, the users must be notified of the change for the connection to
be successful. For instance, when the Administrator changes the HTTP port of the camera whose IP
address is 192.168.0.100 from 80 to 8888, the users must type in the web browser “http://192.168.0.
100:8888” instead of “http://192.168.0.100”.
Vicon recommends keeping the default port 80.
“Secondary HTTP port”-
It supports alternate port to access HTTP server; default is 8080.
“Access name for stream 1
~
5”-
This is the access URLs of the streams 1-5 for making
connection from client software when its codec type is JPEG.
This is not applicable for ViconNet.
Use http://<ip address>:<http port>/<access name for stream 1 ~ 5> to make connection.
HTTPS (Advanced Mode)
By default this is set to 443; any port between 1025 and 65535 can
be selected.
Two way audio
“Two way audio port”-
The default port is 5060. The user can change this value from 1025 to
65535.
After being changed, the external Two-Way audio client program must be changed to the same
server port of connection.
This is not applicable for ViconNet.
FTP (Advanced Mode) This is not applicable for ViconNet.
“FTP port”
- The default port is 21. The user can change this value from 1025 to 65535.
After the change, the external FTP client program must be changed to the same server port
of connection.
RTSP Streaming (Advanced Mode)
To utilize RTSP streaming authentication, be sure a password is set
first.
The default values are recommended for ViconNet.
“Authentication”-
This supports disable, basic and digest modes. In basic mode, the password is sent in
plain text; digest mode encrypts the password, providing higher security.
“Access name for stream 1
~
5”-
This is the access URL of streams 1-5 for making connection from
client software when the codec type is MPEG-4. Use rtsp://<ip address>/<access name for stream 1 ~ 5> to
make connection.
“RTSP port”-
This can be other than the default Port 554; any port between 1025 and 65535 can
be selected. This controls the delivery of streaming media.
“RTP port for video”-
The video channel port for RTP. It must be an even number; default is 5556.
“RTCP port for video”-
The video channel port for RTCP. It must be the port number of video RTP plus 1;
default is 5557.
“RTP port for audio”-
The audio channel port for RTP. It must be an even number; default is 5558.
This is not applicable for ViconNet.