Figure 2.4 UMIQ Module Configuration
The UMIQ-v1 module has a single RJ45 port to connect to the appliance. The UMIQ-v2 module has two RJ45 ports. You can
connect either one to the appliance and the other to a dedicated service processor port on the server. The cable length can
be up to 100 meters long.
See
on page 53 for more information about KVM targets.
2.4 Turning On the Appliance
The appliance is supplied with dual power supplies.
To turn on the appliance:
1.
Plug the power cables into the appliance and into a power source.
2.
Turn on the connected devices.
2.5 Verifying the Connections
2.5.1 Front and rear panel power status LEDs
The front panel of appliance has a dual-color general status LED that may illuminate:
•
The LED illuminates green when the appliance is turned on and operating normally.
•
The LED blinks green when the appliance is booting.
•
The LED illuminates amber if a fault condition occurs, such as power supply failure, elevated ambient
temperature or fan failure. The LED will continue to illuminate amber as long as the failure persists.
Vertiv
| Avocent® Universal Management Gateway Appliance Installer/User Guide |
9