W e b S e r v e r I n t e r f a c e
3-79
The table below shows the possible file operations.
Note that when updating the application software using a
.HEX
file, the
filename should have the form
xxAPxxxx.HEX;
the
AP
indicates the file is
an application load. When updating the boot software, the filename should
have the form
xxWBxxxx.HEX
; the
WB
indicates the file is a boot load.
Password
The Password Details screen (Figure 3.78) is used to modify the password
that restricts access to the Web Server interface.
Acceptable characters for use in a password are digits 0–9 and letters A–Z
and a–z, for a total of 62 distinct characters.
Figure 3.78
Password Details Screen
To change either the Admin or Read-Only password, you must enter it once
in the New Password field and then re-enter the same password in the
Confirm Password field. After entering the new password in both these fields,
click the “Change Admin Password” or the “Change Read Only Password”
button to update and establish the new password.
NOTICE:
Remember that passwords are case-sensitive. When logging on,
password must be entered exactly as it was programmed.
Log Out
The Log Out screen (Figure 3.79) is used to log the current user off of the
Web Server.
Operation
Filename Extension
Action
Update Application Firmware
.CHX or .HEX(1)
Get
Update Boot Firmware
.HEX(2)
Get
Save Configuration Setup
.CFG
Put
Restore Configuration Setup
.CFG
Get
Summary of Contents for WANsuite 6450
Page 1: ...i WANsuite 6450 Reference Manual April 2003 34 00326 C...
Page 4: ...iv W A N s u i t e 6 4 5 0...
Page 10: ...x W A N s u i t e 6 4 5 0...
Page 14: ...xiv W A N s u i t e 6 4 5 0...
Page 24: ...1 10 W A N s u i t e 6 4 5 0...
Page 28: ...2 4 W A N s u i t e 6 4 5 0...
Page 190: ...4 82 W A N s u i t e 6 4 5 0...
Page 200: ...A 10 W A N s u i t e 6 4 5 0...
Page 204: ...B 4 W A N s u i t e 6 4 5 0...