W e b S e r v e r I n t e r f a c e
3-15
T1 Zero Suppression
Determines whether ones density insertion is activated after 15 zeros. This
parameter is ignored if the Coding parameter is set to “B8ZS.”
Values: Disable, Enable
Default: Disable
T1 Mode
As a T1, the unit will operate in either long-haul or short-haul mode.
Values: Short-Haul, Long-Haul
Default: Short-Haul
T1 Line Build Out
Sets the transmit Line Build Out (LBO) for the CBR interface.
Values: 0,
−
7.5,
−
15.0,
−
22.5 dB
Default: 0 dB
T1 DSX Level
Specifies the T1 DSX output level.
Values: 0
−
110, 111
−
220, 221
−
330, 331
−
440, 441
−
550, 551
−
660, >661 ft
Default: 0
−110
ft
E1 CRC4 Mode
Provides line integrity detection to determine if bit errors are present on the
line.
Values: Disable, Enable
Default: Disable
Error Status and Alarm Thresholds Table
The unit can be programmed to generate an alarm condition based on a
specific level of performance degradation. The CBR screen presents a table
that provides current error status and alarm threshold information.
Acceptable alarm thresholds are set for periods of 15 minutes (900 seconds)
and sampled every second. The error types listed in the following paragraphs
can be preset to a value between 0 and 900 seconds. Setting a field to “0”
(zero) disables the alarm on that statistic. To effectively disable alarm
reporting, set all fields to “0” (zero).
The 15-minute time frame is not based on the TR 54016 or T1.403 interval
boundaries, but is a time window based on the accumulated counts over the
previous fifteen 1-minute intervals. In all cases, if the number of actual
network errored seconds in the previous 15 minutes reaches the preset
threshold for the specified error type, an alarm condition is declared.
The four columns of the status table are as follows:
•
Status: Displays the current status of the CBR port.
•
Alarm: Displays the alarm value of the network port. The unit declares an
alarm as soon as the count exceeds the threshold set.
•
Count: Displays the number of events or occurrences of this statistic that
have been detected.
•
Threshold: Displays a read/write field that can be set to a desirable
threshold.
The table provides error status and alarm threshold information for the
following error parameters:
Summary of Contents for WANsuite 6450
Page 1: ...i WANsuite 6450 Reference Manual April 2003 34 00326 C...
Page 4: ...iv W A N s u i t e 6 4 5 0...
Page 10: ...x W A N s u i t e 6 4 5 0...
Page 14: ...xiv W A N s u i t e 6 4 5 0...
Page 24: ...1 10 W A N s u i t e 6 4 5 0...
Page 28: ...2 4 W A N s u i t e 6 4 5 0...
Page 190: ...4 82 W A N s u i t e 6 4 5 0...
Page 200: ...A 10 W A N s u i t e 6 4 5 0...
Page 204: ...B 4 W A N s u i t e 6 4 5 0...