3-8
W A N s u i t e 6 4 5 0
Figure 3.6
Configuration Profile Details Screen
This screen lets you configure or change the following information about the
selected configuration profile:
Wire Mode
Displays the type of wire interface used by the span. The WANsuite 6450
supports only the two-wire mode.
Data Rate (Min)
Sets the minimum attainable data rate in the span.
Data Rate (Max)
Sets the maximum attainable data rate in the span. Note that the line rate will
be 8 kbps above the data rate.
Remote
Enables/disables support for remote management of the units in an SHDSL
line from the STU-R via the EOC.
Values: Enabled, Disabled
Default: Enabled
Transmission Mode
Sets the regional setting of the span represented as a bit-map of possible
settings.
Values: Annex-A (ITU-T G.991.2), Annex-B (ITU-T G.991.2)
Default: Annex-B
NOTICE:
When the WANsuite 6450 is operating with Unit Type set to TU-R, it
supports Annex-A or Annex-B. The configuration of the TU-C unit
determines the actual transmission mode used.
PSD Type
Sets the use of symmetric Power Spectral Density (PSD) mask.
Values: Symmetric
Default: Symmetric
Line Probe
Enables or disables rate adaptation line probe.
Values: Enabled, Disabled
Default: Enabled
Summary of Contents for WANsuite 6450
Page 1: ...i WANsuite 6450 Reference Manual April 2003 34 00326 C...
Page 4: ...iv W A N s u i t e 6 4 5 0...
Page 10: ...x W A N s u i t e 6 4 5 0...
Page 14: ...xiv W A N s u i t e 6 4 5 0...
Page 24: ...1 10 W A N s u i t e 6 4 5 0...
Page 28: ...2 4 W A N s u i t e 6 4 5 0...
Page 190: ...4 82 W A N s u i t e 6 4 5 0...
Page 200: ...A 10 W A N s u i t e 6 4 5 0...
Page 204: ...B 4 W A N s u i t e 6 4 5 0...