6.6.4.36 Belt control (analog output 1)
Display:
Analog output 1 (general applications) / upper belt (forming
machine 250) / feed belt (minced meat portioner MMP 220)
Unit:
Per cent [%] / Volts [V]
Resolution:
1 % / 0.1 V
Setting range:
1 – 100 % / 0.0 - 10.0 V / -1 = Speed
Application:
External output / forming machine 250 / minced meat por-
tioner MMP 220
• Enter speed.
• Press
Enter
.
This function is used to set the speed of an external drive (e.g. feed belt).
The setting range of 0 - 100 corresponds to 0 - 10 Volt.
If you select “-1”, the speed of the master and slave machines is
synchronised. The speed reflects a voltage value (e.g. 10% = 1 V)
The name for analog output 1 can be edited on the “View” page.
6.6.4.37 Belt control (analog output 2)
Display:
Analog output 2 (general applications) / lower belt (forming
machine 250) / transport belt (minced meat portioner MMP
220) / belts for kebab line)
Unit:
Per cent [%] / Volts [V]
Resolution:
1 % / 0.1 V
Setting range:
1 – 100 % / 0.0 - 10.0 V / -1 = Speed
Application:
External output/kebab line and forming machine 250/
minced meat portioner MMP 220
• Enter speed.
• Press
Enter
.
This function is used to set the speed of an external drive (e.g. transport belt).
The setting range of 0 - 100 corresponds to 0 - 10 Volt.
If you select “-1”, the speed of the master and slave machines is
synchronised. The speed reflects a voltage value (e.g. 10% = 1 V)
The name for analog output 2 can be edited on the “View” page.
Summary of Contents for 160.0215
Page 8: ......
Page 10: ...ROBOT HP7E HP10E HP12E HP15E HP20E 0 Foreword 0 2 VEMAG 2010...
Page 22: ...ROBOT HP7E HP10E HP12E HP15E HP20E 2 Description 2 8 VEMAG 2010...
Page 32: ...ROBOT HP7E HP10E HP12E HP15E HP20E 3 Installation and commissioning 3 10 VEMAG 2010...
Page 58: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 12 VEMAG 2010 USB stick plugged in...
Page 60: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 14 VEMAG 2010 Mode group Mode View...
Page 64: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 18 VEMAG 2010...
Page 66: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 20 VEMAG 2010...
Page 68: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 22 VEMAG 2010...
Page 100: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 54 VEMAG 2010...
Page 102: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 56 VEMAG 2010...
Page 112: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 66 VEMAG 2010...
Page 128: ...ROBOT HP7E HP10E HP12E HP15E HP20E 7 Cleaning 7 16 VEMAG 2010...
Page 164: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 12 VEMAG 2010 10 8 Hydraulic plan...
Page 168: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 16 VEMAG 2010...