ROBOT HP7E / HP10E / HP12E / HP15E / HP20E
6. Graphical control
6-34
© VEMAG 2010
6.6.4.9 Metal detection
Display:
Metal detection
Selection:
Off / Manual / Reject system
Unit:
Gramme [g] / Milliseconds [ms] / Speed [%]
Resolution:
1 g / 1 ms / 1 %
Setting range:
1 – 2,000 g / 10 – 2,000 ms / 10 – 100 %
Application:
Metal detector
• Enter weight/delay time and speed.
• Press
Enter
.
Metal detection has two functions.
1. Manual removal of the foreign body. The foreign body is rejected
at a defined weight and speed.
2. Automatic removal of the foreign body using the reject system.
The foreign body is rejected at a defined delay time and speed.
6.6.4.10 Vacuum control
Display:
Vacuum control
Selection:
Off / Time
Unit:
Seconds [sec] / Milliseconds [ms]
Resolution:
0.1 sec / 1 ms / 1 ms
Setting range:
0.1 – 25.5 sec / 0 – 99,999 ms (default = 5,000) /
0 – 99,999 ms (default = 15,000)
Application:
Automatic vacuum control (optional)
• Enter venting time.
• Press
Enter.
The stop valve closes and the feed system is vented for the set time
in order to reduce the vacuum in pauses.
• Enter switch-on delay.
• Press
Enter
.
The machine restarts following the set switch-on delay. This ensures
that the required vacuum can be built back up.
• Enter switch-off delay.
• Press
Enter.
The machine stops, the vacuum is switched off after the set switch-off
delay and the feed system is vented.
Summary of Contents for 160.0215
Page 8: ......
Page 10: ...ROBOT HP7E HP10E HP12E HP15E HP20E 0 Foreword 0 2 VEMAG 2010...
Page 22: ...ROBOT HP7E HP10E HP12E HP15E HP20E 2 Description 2 8 VEMAG 2010...
Page 32: ...ROBOT HP7E HP10E HP12E HP15E HP20E 3 Installation and commissioning 3 10 VEMAG 2010...
Page 58: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 12 VEMAG 2010 USB stick plugged in...
Page 60: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 14 VEMAG 2010 Mode group Mode View...
Page 64: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 18 VEMAG 2010...
Page 66: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 20 VEMAG 2010...
Page 68: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 22 VEMAG 2010...
Page 100: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 54 VEMAG 2010...
Page 102: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 56 VEMAG 2010...
Page 112: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 66 VEMAG 2010...
Page 128: ...ROBOT HP7E HP10E HP12E HP15E HP20E 7 Cleaning 7 16 VEMAG 2010...
Page 164: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 12 VEMAG 2010 10 8 Hydraulic plan...
Page 168: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 16 VEMAG 2010...