ROBOT HP7E / HP10E / HP12E / HP15E / HP20E
6. Graphical control
6-42
© VEMAG 2010
Working with the automatic separation valve
6.6.4.27 Separation valve
Display:
Separation valve
Selection:
Off/In portion/Portion end/Line end/Line start/Group end
Unit:
Milliseconds [ms]
Resolution:
1 ms
Setting range:
0 – 9,999 ms
Application:
When a “Portion end” signal is given, portion with the auto-
matic separation valve.
• Enter the time for which the separation valve is to open.
• Press
Enter
.
Select "In portion" if the separation valve is to open during the portion.
Select "Portion end" if the separation valve is to open at the end of the
portion. Select "Line end" if the separation valve is to open at the end
of a line (end of a casing).
6.6.4.28 Separation interval
Display:
Separation interval
Unit:
Number
Resolution:
1
Setting range:
0 – 99
Application:
Portioning with automatic separation valve
• Enter the number of intervals within a portion in which the separation
valve is to open.
• Press
Enter
.
This parameter is only active if you have selected "In portion" for the
parameter "Separation valve".
6.6.4.29 Valve offset
Display:
Valve offset
Unit:
Milliseconds [ms]
Resolution:
1 ms
Setting range:
-3,000 – +3,000 ms
Application:
Portioning with automatic separation valve
• Enter the offset at which the separation valve is to open at the end of
a portion.
• Press
Enter
.
This parameter is only active if you have selected “Portion end” or “Group
end” for the parameter “Separation valve”. Negative entries are limited by
portion time and positive entries by the pause.
Summary of Contents for 160.0215
Page 8: ......
Page 10: ...ROBOT HP7E HP10E HP12E HP15E HP20E 0 Foreword 0 2 VEMAG 2010...
Page 22: ...ROBOT HP7E HP10E HP12E HP15E HP20E 2 Description 2 8 VEMAG 2010...
Page 32: ...ROBOT HP7E HP10E HP12E HP15E HP20E 3 Installation and commissioning 3 10 VEMAG 2010...
Page 58: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 12 VEMAG 2010 USB stick plugged in...
Page 60: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 14 VEMAG 2010 Mode group Mode View...
Page 64: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 18 VEMAG 2010...
Page 66: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 20 VEMAG 2010...
Page 68: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 22 VEMAG 2010...
Page 100: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 54 VEMAG 2010...
Page 102: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 56 VEMAG 2010...
Page 112: ...ROBOT HP7E HP10E HP12E HP15E HP20E 6 Graphical control 6 66 VEMAG 2010...
Page 128: ...ROBOT HP7E HP10E HP12E HP15E HP20E 7 Cleaning 7 16 VEMAG 2010...
Page 164: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 12 VEMAG 2010 10 8 Hydraulic plan...
Page 168: ...ROBOT HP7E HP10E HP12E HP15E HP20E 10 Appendix 10 16 VEMAG 2010...