Appendix
VFD700 AC Drive Getting Started Guide 91
ID
Function
Range
Step
Default
Change
Mode
Modbus
Register
Address
P00.05
AI1 mode
selector
(P08.02)
0: 0mA
~
20mA
1: 20 mA
~
0mA
2: 4mA
~
20mA
(current loosing with
trip)
3: 20mA
~
4mA
(current loosing with
trip)
4: 4mA
~
20mA
(current loosing
without trip)
5: 20mA
~
4mA
(current loosing
without trip)
6: 0V
~
10V
1
6
Stop Only
0004H
P00.06
Preset1
(P04.01)
± Max. reference
0.01Hz
5.00Hz
Run&Stop
0005H
P00.07
Max. frequency
(P01.02)
0.00Hz
~
300.0Hz
0.01Hz
50.00Hz
Stop Only
0006H
P00.08
Min. frequency
(P01.03)
0.00Hz
~
Max.
frequency
0.01Hz
0.00Hz
Stop Only
0007H
P00.09
Accel. time 1
(P02.04)
0.0
~
3600.0
0.1
10.0
Run&Stop
0008H
P00.10
Decel. time 1
(P02.05)
0.0
~
3600.0
0.1
20.0
Run&Stop
0009H
P00.11
Stop mode
(P03.10)
0: Ramp
1: Coasting
2: Ramp+ DC
injection
3: Ramp +coast
1
0
Stop Only
000AH