Appendix
VFD700 AC Drive Getting Started Guide
145
3 Multistage velocity setup guide
Controlled by terminals, the reference is the value of P04.01 (preset 1)
~
P04.16 (preset 16).
Use the default setup as an example:
P09.05=0
DI4 is preset select bit 0
P09.06=1
DI5 is preset select bit 1
There aretwo operation modes:
When the reference source is preset, terminal status is as shown below:
Table 4-1 Preset and preset terminal status corresponding table 1
DI5 Status (bit 1)
DI4 Status (bit 0)
Speed
OFF
OFF
Preset1 (P04.01)
OFF
ON
Preset2 (P04.02)
ON
OFF
Preset3 (P04.03)
ON
ON
Preset4 (P04.04)
When the reference source is not preset, terminal status is as shown below:
Table 4-2 Preset and preset terminal status corresponding table 2
DI5 Status (bit 1)
DI4 Status (bit 0)
Speed
OFF
OFF
Keep the frequency setting
OFF
ON
Preset2 (P04.02)
ON
OFF
Preset3 (P04.03)
ON
ON
Preset4 (P04.04)
For16 presets (P04.01
~
P04.16) control, please refer to Menu P04.
16
multistage velocity setup guide:
When setting up P01.01
=
2 (reference sourse is multistage velocity), set up
P09.05=0 DI4 controls multistage velocity 0
P09.06=1 DI5 controls multistage velocity 1
P09.08=17 DI6 controls multistage velocity 2
P09.01=1Advanced application of digital input terminals
P09.05=1.15 DI4 controls multistage velocity 0
P09.06=1.16 DI5 controls multistage velocity 1
P09.07=1.17 DI6 controls multistage velocity 2
P09.08=1.18 DI7 controls multistage velocity 3