14 Host Debugging Instruction
263 SD780 Series Servo Technical Manual
14.5.3 Program JOG
The JOG operation of the program refers to the function of executing the continuous operation in
the previously set operation mode (moving distance, moving speed, acceleration/deceleration time,
waiting time, number of movements). This function is the same as the JOG operation, and the
upper apparatus is not connected during the setting. The servo motor operation can be confirmed
and a simple positioning operation can be performed.
Step:
a). Click on
of the main interface of the host computer to enter the program jog operation
process, and then click on [Next] to enter the parameter adjustment interface and set related
parameters as required. The detailed interface is as shown in the figure below.
b). After setting the corresponding parameters, click on [Next] → [Write] → [Next] → [Enable] →
[Execution] → [Next] → [Complete]. The program JOG operation process ends.
14.5.4 Mechanical Characteristics
Mechanical analysis characteristics mean that the servo unit performs automatic operation
(positive and negative reciprocating motion) without issuing an instruction from the host computer,
and the function of estimating the common vibration frequency of the mechanical system during
operation is performed.
Step:
a). Click on
of the main interface of the upper computer to enter the mechanical
characteristics analysis operation process, click on [Next] → [Next] to enter the parameter