exterior terminal operation orders will be blocked while the inverter
close-down at the same time. At this moment, you need to unlock
exterior terminal close-down order, then the exterior operation order
will be valid again. It is same with the communication control.
3, Under keyboard control, the direction order of the exterior terminals
(REV) precede over the direction order of the keyboard; that is, when
(REV) and (COM) is connected, the operation direction given by the
keyboard order is conversed, and restore the original operation
direction after disconnection.
E-02 Frequency
given
main
channel selection
range:0~12
Factory
setting:0
It is used to select the main input channel for the frequency inverter
given frequency, which directly controls or affects the output frequency.
Terminal ( VS2 ) voltage signal and program control channel will also
directly control the operation direction of the frequency inverter. When
restoring the factory settomg, the parameter values will not be changed.
0:Keyboard number given The given frequency the convcy of the main
channel is determined and amended by the parameters [E-16]. When inverter
is on operating state or close down state , the current setting values of
the parameters [E-16] can directly be amended through the Up-down key.
1:Keyboard potentiometer The given frequency of the main channel is
determined and amended by the potentiometer above the keyboard.
2:Terminal VS1 voltage signal 0~10V The given frequency of the main
channel is determined and amended by the input analog quantity of the
control terminal (VS1);If you want more detail about the input analog
quantity and the corresponding relation of the frequency and input analog
quantity filtering time ,please refer to parameter[F-41、F-42、F-43、
F-56、F-57、F-58].
Summary of Contents for AC60 series
Page 1: ...Manual AC60 series frequency inverter Version V2 0...
Page 30: ...26...
Page 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Page 46: ...42 2 Double display keyboard parameter setting mode...
Page 162: ...158 8 2 2 Over current...
Page 163: ...159 8 2 3 Over voltage...
Page 164: ...160 8 2 4 Supply voltage is too low...
Page 165: ...161 8 2 5 Inner inverter over heat...
Page 166: ...162 8 2 6 Over load...
Page 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Page 168: ...164 8 2 9 Motor does not rotate...