96
This parameter is defined as the ratio of stall protection current value
to motor rated current value ration.
G model factory setting:160%
P model factory setting:120%
Stall protection current limit function is real-time monitoring the load
current during acceleration, auto-limit it not to exceed the current limit
setting value(frequency inverter controls the output current by stopping
acceleration or reducing output frequency), to prevent the fault trip which
caused by excessive currents. This function is especially suitable for some
loads with larger inertia or drastic change.
The fiducial value of this parameter is frequency rated current; If use
this function, the acceleration time maybe prolonged. During the frequency
inverter start process, if frequency inverter can not accelerate to the given
frequency as expected and fluctuates in a relative changeless frequency range,
it shows that the limiting current function is in action. At this moment, user
should lighten the load or adjust correlation parameter.