46
E-19
Reserve
113H
E-20
Carrier frequency
0.7KHz~15.0KHz
※
●
78
114H
E-21
Carrier
Characteristics
LED single digit: Carrier
frequency associated with
the output setting
0 : Output frequency
correlation invalid
1
:
Input
Frequency
correlation valid
LED “10” digit: Carrier
temperature correlative
setting
0 : Module temperature
Correlation invalid
1 : Module temperature
Correlation valid
LED “100” digit: PWM
mode options
0:Fixed PWM
1:Random PWM
LED 1000 digit:reserved
0000
●
79
115H
E-22
Slip
frequency
compensation
0~200%
0
〇
80
116H
E-23
Energy-saving
running options
0:Invalid
1:Valid
0
〇
81
117H
E-24
Voltage
auto-adjustment
function
0:Invalid
1:Global valid
2:Only
deceleration
invalid
0
●
81
118H
E-25
Jog frequency
0.00Hz ~ upper limit
frequency
5.00
●
81
119H
E-26
Jog acceleration
time
0.1~6500.0 second
2.0
●
81
11AH
E-27
Jog deceleration
time
0.1~6500.0 second
2.0
●
81
11BH
E-28
Start-up frequency 0.00~60.00Hz
0.50
〇
82
11CH
E-29
Start-up frequency
duration
0.0~20.0 second
0.0
〇
82
11DH
E-30
Start-up options
0 : Start by start-up
frequency
1:Firstly DC braking,then
start by the start-up
0
〇
83
11EH
Summary of Contents for AC60 series
Page 1: ...Manual AC60 series frequency inverter Version V2 0...
Page 30: ...26...
Page 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Page 46: ...42 2 Double display keyboard parameter setting mode...
Page 162: ...158 8 2 2 Over current...
Page 163: ...159 8 2 3 Over voltage...
Page 164: ...160 8 2 4 Supply voltage is too low...
Page 165: ...161 8 2 5 Inner inverter over heat...
Page 166: ...162 8 2 6 Over load...
Page 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Page 168: ...164 8 2 9 Motor does not rotate...