60
selection
H-30
Upper limit
demarcative values
lower limit
demarcative values ~
100.0%
100.0
●
141
31EH
H-31
lower limit
demarcative value
0.0%~Upper limit
demarcative values
0.0
●
141
31FH
H-32
Program run mode
0:single cycle (time in
seconds)
1 : continuous cycle
(time in seconds)
2:single cycle,
continuous running
(time in seconds)
3:single cycle (time in
minute)
4 : continuous cycle
(time in minute)
5:single cycle,
continuous running
(time in minute)
0
〇
141
320H
H-33
Program
breakpoint restore
mode selection
0:operation according
to the first step
speed
1:re-timing and
running according
to the be interrupted
running frequency
2:running according to
the residue time after
being interrupted
running frequency
0
〇
143
321H
H-34
In program run
state,power
off
storage selection
0 : Power off without
storage
1 : Power off with
storage
0
〇
143
322H
H-35
First step speed
direction
and
ace&dece time
0:Forward Rotating;
acceleration time
1/deceleration time 1
1:Forward Rotating;
acceleration time
2/deceleration time 2
0
●
145
323H
H-36
Second step speed
direction
and
ace&dece time
1
●
145
324H
H-37
Third step speed
2
●
145
325H
Summary of Contents for AC60 series
Page 1: ...Manual AC60 series frequency inverter Version V2 0...
Page 30: ...26...
Page 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Page 46: ...42 2 Double display keyboard parameter setting mode...
Page 162: ...158 8 2 2 Over current...
Page 163: ...159 8 2 3 Over voltage...
Page 164: ...160 8 2 4 Supply voltage is too low...
Page 165: ...161 8 2 5 Inner inverter over heat...
Page 166: ...162 8 2 6 Over load...
Page 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Page 168: ...164 8 2 9 Motor does not rotate...