44
running
12:Terminal selection
E-03
Frequency
given
auxiliary channel
selection
0:keyboard number setting
1:Keyboard potentiometer
2 : Terminal VS1 voltage
signal,0~10V
3 : Terminal AS current
signal,4~20mA
4 : Terminal VS2 voltage
signal,-10~10V
5:Terminal pulse signal
6 : RS485 communication
port
7:Ascend、descent control
8:Normal PID running
9 : Constant voltage PID
control
10:Program running
0
〇
69
103H
E-04
Frequency
given
channel gain
0.01~5.00
1.00
〇
71
104H
E-05
Frequency
given
channels
combinations mode
0 : Main channel valid,
auxiliary
channel
invalid
1: Auxiliary channel valid,
main channel invalid
2 : Both channels arbitrary
nonzero value valid, the
main channel priority
3 : Main channel + ( K ×
auxiliary channel)
4 : Main channel - ( K ×
auxiliary channel)
5 : MAX[Main channel,(K ×
auxiliary channel)]
6 : MIN[Main channel,(K ×
auxiliary channel)]
7 : Auxiliary channel +(K ×
Main channel)
8 : Auxiliary channel -(K ×
Main channel)
9 : MAX[(K × Main channel),
auxiliary channel]
10: MIN[(K×Main
channel), auxiliary
channel]
0
〇
71
105H
Summary of Contents for AC60 series
Page 1: ...Manual AC60 series frequency inverter Version V2 0...
Page 30: ...26...
Page 44: ...40 2 Double display keyboard cycle switch the display of monitoring parameter mode...
Page 46: ...42 2 Double display keyboard parameter setting mode...
Page 162: ...158 8 2 2 Over current...
Page 163: ...159 8 2 3 Over voltage...
Page 164: ...160 8 2 4 Supply voltage is too low...
Page 165: ...161 8 2 5 Inner inverter over heat...
Page 166: ...162 8 2 6 Over load...
Page 167: ...163 8 2 7 No display 8 2 8 Motor heat...
Page 168: ...164 8 2 9 Motor does not rotate...