Ethernet
© VeEX Inc. All Rights Reserved.
176
l
Built-in MTIE/TDEV Wander Analysis
l
VeEX MTIE/TDEV Wander Analysis PC software
Recovered Clock Wander Measurements
In 1GE/10GE test mode, the Wander Measurement function may be found under the Advanced Tools menu,
provided that SyncE slave mode is enabled.
Wander Measurements Setup
SyncE Wander Measurements Setup
l
Measurement Clock Reference
reflects the selection chosen from
l
Test Mode:
Select between Manual start/stop and Timed measurements. If Timed is selected, users
can set the length of the test in seconds, minutes, hours or days. Once the selected time has
elapsed the test automatically stops.
l
Save TIE
can be turned ON to write all wander measurements to a FAT32 USB Memory stick in real
time, to be analyzed later on.
l
Sampling Rate
(samples per second) can be set to 1/s, 5/s, 10/s or 30/s, depending on the applic-
ation. 30/s is recommended.