Ethernet
© VeEX Inc. All Rights Reserved.
30
Select the operation mode and the interfaces that will be used to carry out tests. Once the operating mode and
interfaces are selected, independently configure the auto-negotiation, speed, duplex, and flow control settings
for each port (where applicable).
After configuring settings, tap
Apply
to save changes. Tap
Discard
to revert to previous selections.
100/1000Base-X Port Setup
100/1000Base-X and 100/1000Base-T Port
l
Auto Negotiation:
On or Off. Matches the test set’s negotiation settings to those of the link partner
l
Speed
(only when Auto Negotiation is Off for 100/1000T)
: 10 Mbps, 100 Mbps, or 1000 Mbps
l
Duplex
(only when Auto Negotiation is Off):
Half or Full
l
Advertisement
(only when Auto Negotiation is On for 100/1000 Base-T)
: Default-All or Custom.
Custom options include 10/100/1000M/Half or 10/100/1000M/Full.
l
Flow Control:
TX On, RX On, Both On, or Off
l
When flow control is On, the test set will respond to pause frames received by the link partner
by adjusting the transmit rate
l
When flow control is Off, the test set ignores all incoming pause frames from the link partner
and continues transmitting at the configured transmit rate
l
Clock Offset
(1000 Mbps only)
: The frequency may be offset in parts per million
Summary of Contents for MTX150 Series
Page 1: ...MTX150x User Manual Multi Service Installation Maintenance Test Set P N D07 00 148P Rev B00 ...
Page 11: ...Customer Care 303 Table of Contents VeEX Inc All Rights Reserved 11 ...
Page 171: ...171 VeEX Inc All Rights Reserved Ethernet V FTP Setup Download V FTP Download Results SyncE ...
Page 246: ...Common Functions VeEX Inc All Rights Reserved 246 Bluetooth Devices Bluetooth Scan ...
Page 248: ...Common Functions VeEX Inc All Rights Reserved 248 Bluetooth Devices Bluetooth Scan ...
Page 267: ...267 VeEX Inc All Rights Reserved Common Functions ...