141
© VeEX Inc. All Rights Reserved.
Ethernet
l
Sync Header Error
l
Block Type Error
l
FCS/CRC:
Number of received frames with an invalid Frame Check Sequence (FCS)
l
IP Checksum:
Invalid IP Frame Check sequence
l
TCP/UDP Checksum
(Layer 4 only)
l
Jabber frames:
Number of received frames larger than 1518 bytes containing an invalid FCS
l
Runt frames:
Number of received frames smaller than 64 bytes containing an invalid FCS
l
Giant frames
(Advanced Monitoring - Pass Through Results only):
Number of received frames lar-
ger than 1518 bytes
Throughput Results - Global Errors
The
Global Alarms
screen displays the Current and Total alarm count of all streams:
l
LOS:
Loss of Signal
l
LOSync:
Loss synchronization
l
Service disruption associated with loss of signal:
l
Current:
Duration of the current service disruption
l
Total:
Total accumulated duration of the service disruptions