59
© VeEX Inc. All Rights Reserved.
Ethernet
l
128-255 byte frames
l
256-511 byte frames
l
512-1023 byte frames
l
1024-1279 byte frames
l
1280-1318 byte frames
l
> 1318 byte frames - Jumbo frames
BERT Results - Frame Size
Error Injection
Error injection can be performed during testing. The error type and injection rate are configured in the Error
Injection tab.
l
Error type:
Select from Bit, CRC, IP Checksum (Layer 3, 4 only), Pause, TCP/UDP Checksum
(Layer 4 only). With Pause selected, the unit will transmit a pause frame when
Error Injection
icon
is pressed. The Pause time duration is configurable in units of 512 bit time. At Gigabit Ethernet
speed, this is equivalent to 512 ns. For example, if pause time is set to 1000, the pause duration will
be set to 1000x512 ns.
l
Injection Flow:
The error injection flow determines how the selected errors will be injected.
l
Select a single error injection or specific count.