61
© VeEX Inc. All Rights Reserved.
Ethernet
The selected tests will run automatically. When all the tests are complete the test will stop automatically. If the
BERT test suite needs to be stopped before they are done, then simply press the
Stop
button, located in the
actions drop-down menu. The status of each selected test can be seen in the Results tab.
l
Far-End Unit Controlled with Loop Up/Down Commands
l
If the far-end unit is not manually looped back, then it must first receive a loop up command
from the control unit before the BERT test suite can be started.
l
To loop up the far-end unit with the manual mode loop up/down commands, configure the con-
trol settings mode to manual.
l
Enter the MAC and/or IP address of the far-end unit.
l
Send the loop up command by pressing
Loop Up
.
Once the far-end unit has been looped back, start the test by pressing the
Start
button. When the all of the
selected test are completed, the BERT test suite will stop automatically. Once all tests have been completed
and there is no need to test again, go back to the Control tab, and press the
Loop Down
button. This will send
a loop down command to the far-end unit to remove the loopback that is in place.
BERT Results
Summary
Summary tab:
The following results including the Start (ST) and Elapsed (ET) times are displayed:
l
Line Rate
(Mbps)
:
Negotiated rate of the interface (10M, 100M, or 1000M). This value is always
fixed since it depends on the maximum capacity of the link under test, hence the test interface that is
configured.
l
Framed Rate:
(P MAC/IP VLAN Tag + Type/ CRC) / (P Total
Overhead) * Line Rate % (in Mbps).
l
Data Rate:
Payload / (P Total Overhead) * Line Rate %.
l
Utilization:
% of Line Rate. For example, if we transmit 100Mbps on a 1Gbps interface then the util-
ization value is 10% (or 100Mbps) of the total link capacity (or Line Rate).
l
Number of bytes
l
Pause Frames:
Total number of transmitted and received ethernet pause flow-control frames.
Summary of Contents for MTX150 Series
Page 1: ...MTX150x User Manual Multi Service Installation Maintenance Test Set P N D07 00 148P Rev B00 ...
Page 11: ...Customer Care 303 Table of Contents VeEX Inc All Rights Reserved 11 ...
Page 171: ...171 VeEX Inc All Rights Reserved Ethernet V FTP Setup Download V FTP Download Results SyncE ...
Page 246: ...Common Functions VeEX Inc All Rights Reserved 246 Bluetooth Devices Bluetooth Scan ...
Page 248: ...Common Functions VeEX Inc All Rights Reserved 248 Bluetooth Devices Bluetooth Scan ...
Page 267: ...267 VeEX Inc All Rights Reserved Common Functions ...