2 h
ArdwAre
speCifiCAtions
Type
: PROBA 5 Compact
VDH part number
: 907.000401
Power supply
: 12Vdc
Power consumption
: less than 20 Watts
Safety precautions
: Mount an external switch and fuse as close as possible to the PROBA 5 Compact in order to interrupt the voltage.
Housing dimensions
: Approx 208x191X186mm (WxHxD)
Housing material
: Aluminium
Housing finish
: Anodised aluminum
Front panel
: Anodised aluminum with imprint
Mounting method
: DIN rail
Weight
:
Operation
temperature
: 0 / +40˚C
Storage temperature
: -20 / +60˚C
Operation RH
: 10 / 90 %RH non condensing
Operation
:
•
Ethernet LAN connection using a PC
(full access with VASP software)
•
RS 485 connection using a remote control (limited access).
Input/Output signals
:
•
4x Pt1000 Temperature sensors
(2 wire shielded with shield connected to earth-strip)
A..
Signal line
B.. Common 0V line
:
•
3x Analog inputs for 2 or 3-wire shielded sensors
(with shield to earth-strip)
Individual configurable
+
+12Vdc sensor supply output, Imax. per output 100mAdc
(Imax. total 400mA)
S
Input signal selectable by webpage:
0 .. 1 Vdc
Ri > 50 KOhm (Umax. = 5Vdc)
0 .. 10 Vdc
Ri > 10 KOhm (Umax. = 24Vdc)
4 .. 20 mA
Ri = 50 Ohm (Imax. = 40mA)
-
0V common (for 2 and 3-wire sensors)
•
8x Analog outputs
(2-wire shielded with shield to earth-strip)
Individual configurable
+
Output signal selectable by webpage:
0 .. 1 Vdc
(Imax. 10 mA)
0 .. 10 Vdc
4 .. 20 mA
(Rload max. 450 Ohm)
-
0V common
•
8x Digital contact
(use shielded cable with shield to earth-strip)
Contact current (closed) 5 mAdc
Contact voltage (open) 5 Vdc