PROBA 5
Doc.nr: 190356
Version: 1.0
Page
52
6.2.2 Alarm relays settings
No.
Description
range
units
default
2101
Alarm relay on at absolute alarm
0..2
-
2
0 = No alarm relay
1 = Non fatal alarm relay
2 = Fatal alarm relay
2103
Alarm relay on at relative alarm
0..2
-
1
2105
Alarm relay on after power failure
0..2
-
0
2106
Alarm relay on during cooling failure
0..2
-
0
2107
Alarm relay on during heating failure
0..2
-
0
2109
Alarm relay on during door failure
0..2
-
0
2110
Alarm relay on during fan failure
0..2
-
0
2111
Alarm relay on at maximum gas time
0..2
-
0
2112
Alarm relay on during ventilation failure
0..2
-
0
2113
Alarm relay on during sensor failure
0..2
-
0
2120
Fatal alarm relay can be reset
0..1
-
1
0 = No
1 = Yes
2121
Non-fatal alarm relay can be reset
0..1
-
1
2122
Continue control during external fatal alarm
0..1
-
1