Page
57
PROBA 5
Doc.nr: 190356
Version: 1.0
6.6.3 Fans settings
No.
Explanation
1216
External fan alarm can be set as a fatal alarm
1230
Fans off at absolute minimum alarm.
1231
Fans off at absolute maximum alarm.
1235
Fans off at cooling error.
1236
Fans off at heating error.
1240
The fans can be set at a fixed speed. This speed can be set in a ripening program, in stand-by mode and in a hold mode.
1241
To prevent that the fans wil run on a to low speed, a minimal speed can be set.
1242
A maximum speed can be set to prevent the fans from running at a too high a speed.
1250
Switching the fans off if:
• the door is open
• the fans are blocked
• in both cases
1251
Delay time for switching off the fans when the door is opened. If this value is 0, the fans will be switch off as soon as the
door opens.
1252
Delay time for switching on the fans when the door is closed. If this value is 0, the fans will be switch on as soon as the
door closes.
1280
Must the speed of the fan depend on the difference between the measured control temperature and the setpoint? The
bigger the difference, the faster the fans will run.
1281
The offset for P1280.
1282
The delay time before the speed of the fan will be adjusted. This is to ensure that the speed does not keep changing all the
time.
1283
The P-band for P1280.
1284
The I-time for P1280.