Page
63
PROBA 5
Doc.nr: 190356
Version: 1.0
6.6.13 Analogue outputs settings
No.
Explanation
3210
If the analogue output is used for function 1 or 2, the required range for the 0-10V should be adjusted.
Example: Should the 0-10V correspond to -10/+40°C, this parameter should have the value -10
3211
This parameter belongs to parameter 4110. With this parameter the maximum value of the required range should be
entered.
For the example the value +40 should be entered.
6.6.14 Temperature programs
No.
Explanation
4101..4510
These parameters are used to define the standard values of the ripening programmes.
There are five programmes available. Each programme has its own running time, varying from of 4 to 8 days.
Besides the temperatures per day, the day 0 (warm-up time) and the standby temperatures can also be defined.