background image

+

OK

menu

+

OK

menu

Radio thermostat for thermostatic 

radiator valves

z

 

Settings button 

 (press briefl y) and to go back or 

       cancel (press and hold) 

 

Settings button 

+

 (press briefl y) and OK button for 

       confi rmation of settings (press and hold)

Short press on A+B = menu access

EK760

A

A

B

B

3

2

1

6LE001855B

Description of the thermostat

The  EK760  thermostat  is  designed  to  provide 

comfort and energy savings, and is easily installed 

on  thermostatic  radiator  valves.  It  regulates  the 

ambient temperature and works in association with 

a  home  automation  controller,  such  as  TKP100A 

and/or  with  radio  transmitters  in  the  TRMxxx 

range, allowing you to benefi t from the associated 

functions of programming, check and visualization.

It allows the heating device to regulate according to 

3 temperature levels:
• Comfort

: The desired temperature when you  

   are present within the room. 
• Night setpoint

: The desired temperature during 

   short absences or at night. 
•  Frost Protection

: The minimum temperature 

ensured during extended periods of absence. It 

protects your house from the risk of frost.

1

 Display (temperature / text)

2

 Ongoing temperature bypass indicator

3

 Open window

4

 Ongoing presetting indicator

5

 Frost protection mode activated

6

 Night setpoint heating mode activated

7

 Comfort heating mode activated

8

 Temperature indicator in °C

9

 Low battery level indicator

A

 Safety locking activated

Z

 Radio link confi guration indicator 

Installation and replacement of batteries

Remove the cover of the battery box by pressing 

the cover upwards at the marked location (1) and 

picking it up (2).

Then, place the batteries in the direction indicated 

at the base of the product. 

AA

Changing the batteries has no infl uence on the 

confi guration of the product. 

O

Never use new and old batteries together; 

 

nor should batteries of different brands be  

 

 

used together.

 

Do not use rechargeable batteries! 

 

Respect the correct polarity!

Initial confi guration

Once  the  batteries  are  fi tted,  you  can  select  the 

language  used  on  the  EK760  (English,  French, 

German,  Italian).  The  default  language  used  is 

English, however you can change this selection by 

pressing on the " + " / " - " keys briefl y, then confi rm 

the selected language by pressing and holding on 

the "OK" key.

Installation

After the batteries are inserted, the motor is com-

pletely pushed upwards in order to facilitate instal-

lation. The screen will display 

INST

 (INST may also 

be  selected  from  the  menu,  at  all  times).  Ensure 

installation  only  in  this  position.  Do  not  press  the 

other keys, and the thermostat is ready to be fi tted.

Withdraw the head of the original thermostatic valve 

(caution: only the thermostatic valves can be con-

trolled  by  the  EK760  thermostat).  The  installation 

process  is  to  be  carried  out  without  contact  with 

dirt or water as the valve body remains in place.

The  EK760  is  fully  compatible  with  existing 

thermostatic  valves  using  M30x1.5  threading 

(Honeywell, Landis & Gyr, TA, Heimeier, etc.) using 

the white coupling ring provided.

In  case  of  Danfoss  valves,  it  is  necessary  to  use 

an  adapter  provided  in  addition  to  the  white  ring 

(please refer to the correspondence table below).

Heimeier, Junkers  Gyr, 
MNG, Honeywell, Braukmann 
measured thread : M30x1,5

No adapter needed

Danfoss RAV (The pin joint 
must be attached to the valve 
tappet)

+ Mounted pin

Danfoss RA

Danfoss RAVL

Before  installing  the  adapters,  fully  remove  the 

protection pins marked in grey on the drawing.

If  the  model  of  the  valve  is  different  from  those 

listed  above,  you  must  use  an  optional  adapter 

listed below:
• EK771 for COMAP M28x1.5 valve
•  EK772 for Oventrop M30x1.0 valve
•  EK773 for Vaillant valve
•  EK774 for Herz M28x1.5 valve
•  EK775 for Giacomini valve

Press  and  hold  on  the  "OK"  key  until 

INST

 

disappears so that EK760 can start its installation 

process.  The  device  adapts  to  the  operating 

range of the valve. In some cases, this procedure 

may take several minutes. Once the adaptation is 

completed,  the  EK760  goes  back  to  the  normal 

operating mode.

•  If a new adaptation is necessary (for example if 
 

your radiator does not cool down while in 

 

summer mode), select INSTALLATION from the 

 

menu until adaptation starts.

•    If error 

ERR2

 appears on the screen, fi t the    

  EK760 on the radiator valve and then briefl y    

  remove the batteries to reinitialize.

 

Removal

To remove EK760, set the device in 

INST

 position 

(Please refer to the above chapter), wait for a brief 

moment and then press on the release lock located 

in  the  groove  in  the  lower  part  with  the  fork  tool 

delivered to disconnect.

Subsequently, remove EK760 from the valve body.

Radio Link confi guration

The next step is to confi gure the radio link of EK760, 

to do so there are 2 options:
1.  Using  a  house  automation  controller  such  as 
 

TKP100A,  place  TKP100A  in  product  append 

 

mode, and cfg will appear on the EK760 screen 

 

and  RF  confi guration  will  be  displayed 

 

subsequently. Press and hold on "OK" to start 

 

the link process. At the end of the process, it is 

 

carried out correctly if the display indicates "OK", 

 

on  the  other  hand  the  operation  must  be 

 

repeated  if  it  indicates  "NOK"  (For  more 

 

information,  see  instructions  for  TKP100A).

2.   Using micromodules of type TRM69x or TRM702A,
 

place the micromodule in confi guration mode,

 

and cfg will appear on the   EK760 display screen

 

subsequently.  Press  and  hold  on  "OK"  to  start 

 

the  link  process.  You  can  select  the 

 

desired  function  by  navigating  with  the  "+" 

 

/ " - " key  then confi rming the function selected 

 

by pressing and holding on the "OK" key. 

                    **

*  Function  not  available  with  TRMxxx  radio 

transmitters.

While setting up the radio link, the display will fi rst 

indicate "

Link

". Then, it displays "

OK

" if the radio 

link  has  been  successfully  established  or  "

NOK

if it has not been successfully established. In this 

case, repeat the radio link confi guration process.
If you have selected the timer comfort function, you 

can also set the timer in comfort mode (default is 

set to 3 hrs.). Select the desired time with the "+" / 

"-" keys, then confi rm the selection by pressing and 

holding on the "OK" key.
You can exit the confi guration process at any time 

by  pressing  and  holding  on  the  cancellation  key. 

For "Radio link elimination" and "reset ", see § 4.

Standard operation

In standard operation, the screen will be switched off 

to conserve battery power (it is possible to change 

this setting and leave the screen continuously on, 

please refer to chapter "EK760 setting"). Pressing 

on  the  "+"  /  "-"  buttons  briefl y  will  display  the 

measured temperature, and the 6th and 7th icons 

(indicated at the "Overview of the Thermostat") will 

indicate if the thermostat is in comfort

 mode or 

in 

Night setpoint

 

mode. 

 

From this screen, several options are available:

1.    Consultation of the existing setpoint 
 

temperature

You can check the current temperature setpoint by 

pressing on the "+" or "-" keys briefl y. The current 

temperature setting (Comfort or 

Night setpoint

) will 

fl ash and display for 10 sec, before the measured 

temperature will be displayed again. 

2

.   

Ongoing setpoint temperature bypass 

To  temporarily  change  the  current  temperature 

setpoint,  press  on  the  "+"  or  "-"  key  to  increase 
or reduce the temperature. 
The setpoint temperature will blink, and automatically 

validated after 10 sec or by pressing and holding 

on  the  "OK"  key.  This  bypass  is  valid  until  the 

next  mode  adjustment  (next  step  of  the  heating 

schedule  initiated  by  the  house  automation 

controller TKP100A, for example). 
The icon "

 ongoing temperature bypass indicator" 

will be displayed on the screen to indicate that the 

bypass is in progress.
To  cancel  this  bypass:  press  and  hold  on  the 
"return" key, and the icon "

 ongoing temperature 

bypass indicator" will disappear.

3

.   

Product safety locking

To  avoid  unintentional  activation,  you  can  lock  the 

EK760. For this, press and hold the + /- keys at the 

same  time

 

keys  simultaneously  until  the  " "  icon 

appears on the screen. To deactivate the function,   

repeat  the process until the  " "  icon disappears.

4

.  

EK760 settings

To access the product settings, it is necessary to  

press on the "+" and "–" keys to enter the menu, 

then navigate in the menu by pressing on the "+" 

and "-" buttons briefl y.  To enter one of the settings, 

press and hold on the "OK" key. To exit a setting or 

the menu, press and hold on the "Return" key.

Different settings are accessible:

•  "Mode" : Change of heating mode

There are 2 heating modes on the product (comfort 

and economy). It is possible to change the heating 

mode by selecting the "

Mode

" setting. By pressing 

on  the  "+"  button  briefl y,  you  can  select  "

Conf

(for  Comfort  mode)  or  "

Night

"  (for  night  setpoint 

mode). The selection can be confi rmed by pressing 

and holding on the "OK" key.

•  "Priority" : Forcing of the thermostat heatin mode 

The  priority  mode  allows  you  to  maintain  a 

constant temperature in your house in comfort or 

economy  mode,  but  does  not  take  into  account 

some  programming  profi les  (for  example,  profi les 

available  on  the  house  automation  controller 

TKP100A).  To  select  the  "Priority"  mode  in  the 

menu,  confi rm  selection  by  pressing  and  holding 

on the "OK" key and select the desired mode with 

the "+" / "-" keys:

• 

 Comf.

 : To enter comfort mode

• 

Night

 : To enter night setpoint mode

• 

DIS

 : to disable the priority mode

Confi rm your selection by pressing and holding on 

the "OK" key.

•  "Temperatures" : Adjustment of the temperature 

setpoint for the different heating modes 

 

2

3

4

5 6

7

8

9

A

1

Z

Heating

Function on the EK760 display 

Comfort 

Night setpoint

Heating pause

Heating pause*

S1

Scenario 1

S2

Scenario 2

Temporary

Comfort / Night setpoint

Priority

Priority

                   

Window*

Room temperature*

del

Delete 

/

Specifi cations

Power supply: 4  AA LR6 1.5V batteries 

Battery lifespan: 4 years

Setting range

•   Comfort mode temperature: +5 °C to +30 °C

•     Night setpoint mode temperature: +5 °C to +30 °C

Room temperature display range: 0 °C to +40 °C

Operating temperature: +0 °C to +50 °C

Storage temperature: -20 °C to +70 °C

Ball pressure test temperature 75 °C

Humidity: max 93% at 40 °C

IP: 20

IK: 04

Degree of pollution: 2

Action type: 1.L

Software structure: class A

Dimensions (l x h x d): 74.7 x 48 x 63.1 mm

Emission frequency: 868-870MHz/25mW

Transmitter duty cycle: 0.1

Receiver category: 2

Typical range: >150 m in free range and 50 m (2 slabs).

The "Temperature" mode allows you to adjust the 

temperature setpoint of the different heating modes 

according to the range described in the table below.

Mode

Default 
value

Min

Max

Interval

Comfort

20°C

5°C

30°C*

0,5°C

Night 
setpoint

16°C

5°C

30°C*

0,5°C

Frost 
protec-
tion

6°C

Non-confi gurable on the value 
but through the house auto-
mation controller (for example, 
TKP100A)

*The  maximum  adjustable  temperature  may  be 

limited by remote setting.

Select  the  "Temperature"  mode  in  the  menu  and 

confi rm  selection  by  pressing  and  holding  on  the 

"OK" key:
• When the "Comfort" temperature setpoint blinks,  

you can change it by pressing on the "+" / "-" keys 

briefl y,  then  confi rm  selection  by  pressing  and 

holding on the "OK" key.

•  When  the  "Night"  temperature  setpoint  blinks,   

you can change it by pressing on the "+" / "-" keys 

briefl y,  then  confi rm  selection  by  pressing  and 

holding on the "OK" key.

•  "Heating pause" : Stop heating 

The "Heating pause" mode allows you to turn the 

heater off (for example, during summer). This helps 

to increase the battery lifespan. 

In this mode, only the frost protection and the anti-

scaling functions (1x per week) remains active. 

Select the "Heating pause" mode in the menu and 

confi rm selection by pressing and holding the "OK" 

key, then select "Yes" or "No" by pressing on the " 

+ " and " - " keys briefl y to activate or deactivate the 

function,  then  subsequently  confi rm  by  pressing 

and holding on the "OK" key.

In "Heating pause" mode, the "Mode" and "Priority" 

modes will not be accessible.

EK760 ensures anti-scaling protection of your

      valve through the complete opening/closing 
      of the valve per week.

•  "Window" : Window opening detection

The  EK760  has  an  integrated  window  opening 

detection  function.  If  a  window  opens  leading 

to  a  drastic  fall  in  temperature,  the  EK760  will 

automatically  close  the  radiator  valve  to  save 

energy.  The  screen  will  display  icon  "

",  and 

subsequently resumes its normal operation. 

To  confi gure  this  function,  select  the  "Window" 

mode  in  the  menu  and  confi rm  selection  by 

pressing and holding on the "OK" key, then select 

"Yes" or "No" with a brief press on the " + " and 

" - " keys to activate or deactivate the function then 

confi rm your selection by pressing and holding the 

"OK" key.

Now,  adjust  the  sensitivity  of  the  device  to 

temperature changes. This can be selected with a 

brief press on the " + " and " - " keys ("High"= high 

sensitivity, "Medium" = medium sensitivity (default 

setting),  "Low"=  low  sensitivity),  then  confi rm  by 

pressing and holding on the "OK" key. 

Now,  select  the  time  (ranging  from  10  minutes  to 

60 minutes at an interval of 5 minutes) during which 

the  valve  must  remain  in  frost  protection  mode 

by  pressing  on  the  "+"  and  "-"  keys  briefl y,  then 

confi rm your selection by pressing and holding on 

the "OK" key.

It is also possible to exit the frost protection mode 

due  to  an  open  window  pressing  and  holding  on 

the "enter" key.

•  "Temp Offset" : Temperature calibration  

This  setting  adjusts  the  measured  value  by  the 

thermostat  if  you  are  measuring  a  different  room 

temperature.

To do so, select the "Temp Offset" mode in the menu 

and confi rm selection by pressing and holding on 

the  "OK"  key.  You  can  change  the  temperature 

within  a  limit  of  -5  to  +5°C  with  a  short  press  on 

the "+" / "-" keys, then confi rm your selection by 

pressing and holding on the "OK" key. 

The    temperature  offset  is  canceled  in  "Heating 

pause" mode (summer period)

•  "LCD Standby" : Putting the screen in standby 

Putting  the  screen  in  standby  helps  to  increase 

battery lifespan. This setting provides you with the 

options of permanently activating the screen or to 

put it on standby after 30 sec if no key is pressed. 

To  do  so,  select  the  "LCD  Standby"  mode  in  the 

menu  and  confi rm  by  pressing  and  holding  on 

the  "OK"  key.  With  a  brief  press  on  the  "+"  /  "-" 

keys,  you  can  select  "Yes"  to  activate  the  screen 

standby  function  (default  confi guration)  or  "No" 

to  deactivate  the  function  (the  screen  remains 

permanently  on),  then  confi rm  your  selection  by 

pressing and holding on the "OK" key. 

•  "Installation" : Installation mode 

This function enables the EK760 to enter installation 

mode.

For this, select the "Installation" mode in the menu 

and confi rm by pressing and holding on the "OK" 

key.  Once  the  "

INST

"  fl ashes  on  the  screen,  the 

motor  is  pushed  upwards  and  you  can  install  the 

EK760  on  the  thermostatic  valve.  Once  installed, 

you  can  exit  the  installation  process  by  pressing 

and holding on the “OK” key.

•  "Del radio link" : Clearing of the radio links

This function allows you to clear the existing radio 

links on the EK760.

To  delete  radio  links,  select  the  "Del  radio  link" 

mode  in  the  menu  and  confi rm  selection  by 

pressing  and  holding  on  the  "OK"  key,    and  a 

blinking "OK" message will be displayed. You can 

confi rm the clearing by pressing and holding on the 

"OK" key or cancel the operation by pressing and 

holding on the "Return" key. 

•  "Reset" : restore factory settings

This parameter resets the parameters to the factory 

settings  and  causes  the  elimination  of  the  radio 

links.

To  do  so,  select  the  "Reset"  mode  in  the  menu 

and confi rm selection by pressing and holding on 

the  "OK"  key,  and  a  blinking  " 

OK ?

"  message 

will be displayed. You can confi rm the clearing by 

pressing and holding on the "OK" key, or cancel the 

operation by pressing and holding on the "return" 

key. 

•  "Language" : Language confi guration

This  setting  allows  you  to  select  the  language 

used on the EK760 (English, French, German, and 

Italian).

To do so, select the "

Language

" mode in the menu 

and confi rm selection by pressing and holding on 

the  "OK"  key,  change  the  language  with  a  brief 

press  on  the  "  +  "  /  "  -  "  keys  then  confi rm  your 

selection by pressing and holding on the "OK" key. 

•  "Software version" : Version of software installed 

on the product

This  setting  allows  you  to  know  which  software 

version has been installed on your EK760.

To  do  so,  select  the  "Software  version"  mode  in 

the  menu  and  confi rm  selection  by  pressing  and 

holding on the "OK" key, and the software version 

will  be  displayed.  You  can  exit  this  display  by 

pressing and holding on the "OK" or "Return" key.

What should I do if... ?

The  "Low  battery"  symbol  is  displayed:  please 

change  the  batteries  (4  batteries  of  type  AA  LR6 

1.5V) immediately.

The  application  does  not  detect  EK760  during 

confi guration:  It  is  possible  that  EK760  is  out  of 

range of the house automation controller TKP100A. 

Please bring the TKP100A closer to the EK760.

The screen does not light up when the "+" or "–" 

keys  are  pressed:  Ensure  that  the  batteries  are 

correctly positioned. Use only batteries of type AA 

LR6 1.5V (provided with the product). If the problem 

persists, replace the batteries.

I pressed the "+" or "–" keys before installing the 

EK760  on  the  valve:  Remove  and  reinsert  the 

batteries,  or  select  the  "Installation"  mode  in  the 

menu  and  confi rm  by  pressing  and  holding  on 

the  "OK"  key.  Once  a  blinking  "

Inst

"  message  is 

displayed, the motor is placed in high position, you 

can  install  the  EK760  on  the  thermostatic  valve. 

Once installed, you can exit the installation process 

by pressing and holding on the "OK" key.

The  screen  displays  the  code 

ERR1

  (adaptation 

impossible):

•  The  EK760  is  not  assembled  correctly.  Please    

repeat the assembly steps.

•   The adjustment screw could have fallen. In this

    case,  replace  the  adjustment  screw  and  then 

   remove  the  batteries  briefl y  to  reset  the  device. 

   The  motor  should  be  positioned  completely  at 

    the top to facilitate assembly. The screen indicates 

    "

Inst

" ("Inst" can also be selected in the menu). 

    The continuous threading turns and tightens the 

       new adjustment screw. Proceed with the assembly 

  of  EK760  on  the  thermostatic  valve  again. 

The  screen  displays  one  of  the  following  codes 

ERR2

  (Piston  stroke  too  short)  or 

ERR3

  (Motor 

movement  impossible):  Remove  EK760  from  the 

valve and press on the piston of the thermostatic 

valve body. Repeat the assembly steps.

Correct Disposal of this product

(Waste Electrical & Electronic 

Equipment).

Applicable in the European Union and other 

European countries with separate collection 

systems).

This  marking  shown  on  the  product  or  its  literature 

indicates  that  it  hould  not  be  disposed  with  other 

household  wasted  at  the  end  of  its  working  life.  To 

prevent  possible  harm  to  the  environment  or  human 

health  from  uncontrolled  waste  disposal,  please 

separate this from other types of wastes and recycle it 

responsibly to promote the sustainable reuse of material 

resources.

Household users should contact either the retailer where 

they purchased this product, or their local government 

offi ce, for details of where and how they can take this 

item for environmentally safe recycling.

Business users should contact their supplier and check 

the terms and conditions of the purchase contract. This 

product  should  not  be  mixed  with  other  commercial 

wastes of disposal.

Simplified EU Declaration of Conformity:

As  per  the  present  document,  Hager  Controls  declares  that 

the  radio  equipment  of  the  Radio  thermostat  for  thermostatic 

radiator  valves  EK760  type  is  compliant  with  the  2014/53/UE 

guidelines.

The complete text of the EU Declaration of Compliance is 

available at the following link 

www.hagergroup.net

 

6LE001855B

6LE001855B

6LE001855B

Summary of Contents for EK760

Page 1: ...ery lifespan 4 years Setting range Comfort mode temperature 5 C to 30 C Night setpoint mode temperature 5 C to 30 C Room temperature display range 0 C to 40 C Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Ball pressure test temperature 75 C Humidity max 93 at 40 C IP 20 IK 04 Degree of pollution 2 Action type 1 L Software structure class A Dimensions l x h x d 74 7 x 48 x 63 1...

Page 2: ...eriods of absence It protects your house from the risk of frost 1 Display temperature text 2 Ongoing temperature bypass indicator 3 Open window 4 Ongoing presetting indicator 5 Frost protection mode activated 6 Night setpoint heating mode activated 7 Comfort heating mode activated 8 Temperature indicator in C 9 Low battery level indicator A Safety locking activated Z Radio link configuration indica...

Page 3: ...he thermostat is ready to be fitted Withdraw the head of the original thermostatic valve caution only the thermostatic valves can be con trolled by the EK760 thermostat The installation process is to be carried out without contact with dirt or water as the valve body remains in place The EK760 is fully compatible with existing thermostatic valves using M30x1 5 threading Honeywell Landis Gyr TA Heim...

Page 4: ...e In some cases this procedure may take several minutes Once the adaptation is completed the EK760 goes back to the normal operating mode If a new adaptation is necessary for example if your radiator does not cool down while in summer mode select INSTALLATION from the menu until adaptation starts If error ERR2 appears on the screen fit the EK760 on the radiator valve and then briefly remove the batt...

Page 5: ...icate Link Then it displays OK if the radio link has been successfully established or NOK if it has not been successfully established In this case repeat the radio link configuration process If you have selected the timer comfort function you can also set the timer in comfort mode default is set to 3 hrs Select the desired time with the keys then confirm the selection by pressing and holding on the ...

Page 6: ...eactivate the function repeat the process until the icon disappears 4 EK760 settings To access the product settings it is necessary to press on the and keys to enter the menu then navigate in the menu by pressing on the and buttons briefly To enter one of the settings press and hold on the OK key To exit a setting or the menu press and hold on the Return key Different settings are accessible Mode C...

Page 7: ... not be accessible OEK760 ensures anti scaling protection of your valve through the complete opening closing of the valve per week Window Window opening detection The EK760 has an integrated window opening detection function If a window opens leading to a drastic fall in temperature the EK760 will automatically close the radiator valve to save energy The screen will display icon and subsequently r...

Page 8: ...sing and holding on the OK key or cancel the operation by pressing and holding on the Return key Reset restore factory settings This parameter resets the parameters to the factory settings and causes the elimination of the radio links To do so select the Reset mode in the menu and confirm selection by pressing and holding on the OK key and a blinking OK message will be displayed You can confirm the ...

Page 9: ...om the valve and press on the piston of the thermostatic valve body Repeat the assembly steps Correct Disposal of this product Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its literature indicates that it hould not be disposed with other household wasted at the end of its wo...

Reviews: