162 bright blue Installation Manual
If the
Status
section shows
OK
, then you have successfully linked the AD-400.
Now, to perform a complete operational test of the AD-400:
1
Present your credential to the AD-400. If the door is functioning correctly the card data will appear in the
Card Data
field.
2
Depress the Internal Lever. If the door is functioning correctly the
Interior image
will show an open door.
3
Depress the External Lever. If the door is functioning correctly the
Exterior image
will show an open door.
WRI400 Configuration
Configuration of the WRI400 is accomplished by the SUS while the HHD is connected to the PIM400. After the
PIM400 has been configured you can Link the WRI400 to the PIM400 and address it.
Connecting to HHD/Coupling/Linking
The HHD is used to configure the WRI400. Follow the steps below to connect to the HHD, couple with the HHD,
and Link to the PIM400. For information about the HHD and WRI400 settings, see the Schlage Utility Software
(SUS) User Guide at www.schlage.com/support.
Connecting to the HHD
To connect the HHD to the WRI400:
1
Verify power is connected to the WRI400.
2
Loosen the 4 screws and remove the WRI400 cover. The Power LED should blink when the cover is off.
Note:
The WRI400 will send a tamper signal while the cover is off.
3
Log in to the SUS software (refer to the SUS User Guide for log-in procedure).
Note:
Make sure the HHD connection type is set to
USB Connection
.
4
Connect the HHD to the WRI400 USB port (J5). The WRI400's USB LED (2) will blink green.
▪
The WRI400 is communicating with the HHD when the USB LED blinks green and the HHD display
indicates
WRI400
at the bottom of the main screen. The SUS is now ready to view the WRI400
settings.
5
To Edit Settings or Update Firmware on the WRI400, the SUS software and the WRI400 must be coupled.
Follow the steps below to couple the WRI400 and the HHD.
Coupling with the HHD
1
Connect the WRI400 to the HHD (see section above for details).
2
On the WRI400, press and hold the
SCHLAGE
button while pressing the
LINK
button three (3) times
within 5 seconds. The USB LED will blink red and green.
3
On the SUS, select the option
Couple HHD to Device
. The SUS will report when coupling is successful.
▪
Successful coupling will be indicated on the WRI400 with a blinking green USB LED.
Linking to a PIM400
1
Click
Start
on the HHD. A Menu will open with a list of programs.
2
Select the
Schlage Utility Software
option to open
SUS
.