160 bright blue Installation Manual
9
Go to the
Link
tab.
10
Use the
Select Door
drop down menu to Set the address of the AD-400. This number will be the AD-400's
address.
11
Click
Link
.
12
Put the AD-400 Lock into
Linking Mode
:
a) Hold down the
Exit Request Lever
.
b) While holding down the lever, present a
credential
.
c) The
Schlage
button will blink as will the
Internal Push Button
. The lock is now in
Linking Mode
.
d) Release
Exit Request Lever
.
13
Once the
Stop
option is enabled, the AD-400 is now linked to this PIM400 with the specified address.
Diagnostics
Follow the steps below to determine if you have correctly Linked your AD-400 lock to your PIM400:
1
Log in to SUS (see steps above).
2
Connect the PDA to the PIM400 using the supplied USB cable.