146 bright blue Installation Manual
Contacts, Relays, and Pin Functions
A set of input contacts and output relays are provided on the Schlage VIP Lock. The locks can be ordered with
integrated credential readers.
Input Contacts
▪
Request to Exit (REX), normally open, non-supervised
▪
Door Open Detect (DOD), normally open, non-supervised
▪
Latch bolt monitor (LBM), normally closed, non-supervised
▪
Key position, normally closed, non-supervised
▪
Spare
Output Relays
▪
Solenoid for door strike
▪
Red Led Control
▪
Green Led Control
▪
Beeper Control
Credential Reader Technologies
▪
HID Proximity Credential
▪
Magnetic Stripe Credential
JP1
- RS-485 termination. This jumper must be removed to enable communication between VIP and
bright blue
.
J3
- Power source and communication. Used to connect
bright blue
to the VIP.
J6
- Not used.
Dip Switches
▪
1-4
- Used for addressing the VIP. See the Addressing the VIP section for details.
▪
5
- Used to choose between Fail Secure and Fail Safe
▪
OFF - Fail Secure (FSE)
▪
ON - Fail Safe (FSA)
▪
6
- Used to choose between magstripe and proximity reader.
▪
OFF - Magstripe Reader
▪
ON - Proximity Reader
▪
7
- Used to set protocol type. To communicate with bright blue this must be switched to ON.
▪
OFF - VIP protocol
▪
ON - 'F' series protocol
Note:
Dip Switch 7 MUST be switched to the ON position for the VIP lock to work with
bright blue
.