4.2.6.
Corner location, rear vent
connection, vertical rise, horizontal
termination (Figs 7 & 9)
Manufactured by Miles Industries Ltd., British Columbia, Canada
8
Can be used with either #551DVK standard vent kit
or #984 Dura-vent terminal cap and accessories.
Adapter #817VAK, two 90° vent elbows #990B and
Dura-vent pipe lengths will be required.
(See venting options section of this manual).
No more than two 90°elbows must be used.
All vertical dimensional limits are as section 4.2.3.
The minimum corner location is shown in fig. 9.
4.2.7.
Rear vent connection, vertical vent
rise with through the roof
termination (Fig.10)
Adapter #817VAK, one 90° vent elbow #990B,
Dura-vent pipe lengths, a vertical vent terminal and
roof flashing will be required. Various other ceiling
or roof items may be necessary depending on the
particular installation (See venting options section
of this manual).
4.2.8.
Rear vent connection, vertical vent
rise with offset and through the roof
termination (Fig.11)
For situations where offset is necessary in an attic to
avoid obstructions or allow useful space.
Adapter #817VAK, one 90° vent elbow#990B, two
45° vent elbows #984, wall straps, a vertical vent
terminal, roof flashing and Dura-vent pipe lengths
will be required. Various other ceiling or roof items
may be necessary depending on the particular
installation (See venting options section of this
manual).