5.2.14.
Top vent connection, vertical vent rise
with offset and through the roof
termination (Fig.33)
For situations where offset is necessary in an attic to
avoid obstructions or allow useful space.
Adapter #817VAK, four 45° vent elbows #984, wall
straps, a vertical vent terminal, roof flashing and Dura-
vent pipe lengths will be required. Various other ceiling
or roof items may be necessary depending on the
particular installation (See venting options section of this
manual).
Figure 33
5.3.
Manufactured by Miles Industries Ltd., British Columbia, Canada
19