14.
AERATION SETTING CHECK
The burner is equipped with an adjustable shutter to control
primary aeration. See figure 68. The shutter is factory set at
an aeration gap which will give optimum performance for
the vast majority of installations. In a few unusual
installations performance may be improved by adjusting the
aeration. The need for adjustment should be determined by
operating the appliance with the ceramic fuel effects and
window installed. See the “Final checks” section in this
manual for adjustment details.
The shutter setting is very critical. A change of
1
/
64
” can
make a substantial difference to the performance.
If converted for LPG refer to the instructions supplied
with kit #554LPK for the correct shutter setting.
Figure 68