![Valet Digital Instruction Manual Download Page 49](http://html.mh-extra.com/html/valet/digital/digital_instruction-manual_850947049.webp)
49
Walk Test Mode
Walk test mode should be used when testing the system or after a new
detector has been learnt into the system.
TO ENTER WALK TEST MODE
1.
Safety Lock must
be off
Ensure Safety Lock has been turned off within the
last 5 minutes. See
Section 43.
2.
Press both buttons
for 3 seconds
Enter Programming mode by pressing
buttons 1 & 2
together for
3 seconds
. The siren will
beep 3 times
to confirm you have entered programming mode.
3.
Press 1 time
Within 3 seconds, press
Button 2
to select
special
features
. You will hear
2 beeps
as confirmation.
4.
Press 1 time
Within 30 seconds, press
Button 2
to enter
Walk
Test mode
. You will hear
2 beeps
as confirmation.
5.
Walk Test mode
The system will enter
Walk Test mode.
During this
time, the siren will
beep
the number of times of the
zone
that has been triggered. Detectors, which have
been set to 24 hour mode, will still trigger the alarm.
If the tamper switch is pressed the siren will beep
once.
6.
Press 1 time to exit
Press
Button 2
to exit
Walk Test mode
.