Example: Glue Correction – End
Note: It is assumed that the valve is functioning properly and that the glue pattern is
being applied to the exact locations mentioned in the example.
The Glue Pattern is supposed to start at 20mm from the edge of the tab. The Glue Pattern is
supposed to have a length of 160mm.
Figure 45: Product Glued Correctly
Figure 46: Product Not Glued Correctly
The CGS-40 Sensor identified the Glue Pattern Start at 20mm from the edge of the tab. The
Glue Pattern Length was identified as 163mm long. Meaning, the Inspection Process identified
the Glue Pattern End at 183mm. We have verified that the Glue Pattern on the product started
at 20mm and was 160mm long. Meaning, the Glue Pattern was supposed to End at 180mm. To
help the Inspection Process identify the correct pattern dimensions, we need to
Lower
the
Glue
Correction – End
from “
-8mm”
to “
-11mm”
.
Increasing
the
Glue Correction – End
from
-8mm
to
-5mm
would cause the Glue Pattern’s
End to be identified at 186mm. Meaning, the Glue Pattern’s Length would increase to 166mm.
So, it is important to understand the relationship between this parameter and the Pattern’s End
and Pattern’s Length.