MCP-8I Quick Start Guide
4. Select
each
of the desired ‘
Alarm Activation
’ parameters that need to be suppressed until
the machine speed is above the Sensor Channel’s ‘
Vmin
’ speed, and select the activation
mode to ‘
ON > Vmin
’. Then press the button labeled ‘
APPLY
’.
Figure 117: Setting Alarm On Above Vmin
5. In the same menu, Select the Sensor Channel’s ‘
Vmin
’ setting. Using the thumbwheel
buttons, set the desired machine speed at which the desired alarms can be activated and
press the button labeled ‘
APPLY
’.
Figure 118: Setting the Sensor Channel's Vmin Setting
Note1 –
Products that fail and have the alarm activation suppressed will still be shown on the
control’s display and will be counted in the ‘
Inspection Statistic’s
’ as an
Error.
Note2
– Alarm Activation Suppression
must
be configured for each Inspection Channel.