5-16
Valco Cincinnati, Inc.
Section 5 - Operation
MC090 - MCP-6 Control Unit
EPC12 Application
The ECP12 application regulates pressure, and fires the valve when the
speed threshold is achieved. The default valve type is
MAC24.
All valve channels are designed to trigger from the external Enable signal,
defaulted to Scanner 4.
Valve setup:
Valve setup:
Valve setup:
Valve setup:
Valve setup: Valves 1 – 6 are preset to
Continuous mode, so that only that
pattern screen will be visible .
1.
For each valve under the settings menu, set the speed threshold.
The speed threshold is defaulted to 3 ft/min. This means the valve will only
activate when the machine speed is greater than 3 ft per min.
By default, the external Enable signal is set to Scanner 4, under the
System
Settings menu. It should remain set to 4 because of the board circuitry.
2.
To set the minimum and maximum pressure percentages:
a. Press the Pressure key.