4-16
Valco Cincinnati, Inc.
Section 4 - Programming
MC090 - MCP-6 Control Unit
Compensation Time
x3
x3
x3
x3
x3
On Compensation Time (Ton)
On Compensation Time (Ton)
On Compensation Time (Ton)
On Compensation Time (Ton)
On Compensation Time (Ton) - This is the amount of time (in milliseconds)
from when the valve is activated to when the glue is applied. Increasing the
"ON" Compensation Time will move the start of the pattern forward.
Off Compensation Time (Toff)
Off Compensation Time (Toff)
Off Compensation Time (Toff)
Off Compensation Time (Toff)
Off Compensation Time (Toff) - This is the amount of time (in milliseconds)
from when the valve is turned off to when the adhesive application is stopped.
Increasing the Off compensation time will make the glue line shorter.
Minimum Compensation Time (Tmin)
Minimum Compensation Time (Tmin)
Minimum Compensation Time (Tmin)
Minimum Compensation Time (Tmin)
Minimum Compensation Time (Tmin) - This is the time the valve will be
open, no matter what the pattern length, the machine speed, and the "OFF"
Compensation Times are set at.
Valve Type
The Plus/Minus Buttons can
be used to scroll through the
different valve types
available.
OR
OR
OR
OR
OR