4-17
Valco Cincinnati, Inc.
Section 4 - Programming
MC090 - MCP-6 Control Unit
Check valve/channel 2 settings.
Repeat for all valves being used.
Check Other
Valves/
Channels
Scanner Settings
x2
x2
x2
x2
x2
Encoder Settings
Encoder Input
Encoder Input
Encoder Input
Encoder Input
Encoder Input - Use to choose a scanner (1 through 4) or the encoder Z
pulse to trigger the selected channel.
Correction Factor
Correction Factor
Correction Factor
Correction Factor
Correction Factor - The scaling factor used to adjust an individual/system
ratio for the selected channel. This feature is used on right angle machines
when the valves are mounted in sections that are running at different speeds.
To be as precise as possible, the encoder should always be mounted in the
section that is running the fastest.
Minimum Product Length
Minimum Product Length
Minimum Product Length
Minimum Product Length
Minimum Product Length - The length of a product that is necessary to
trigger a start signal. If there are tabs and/or dust causing false trigger
signals, increase the Minimum Product Length.
Maximum Product Length
Maximum Product Length
Maximum Product Length
Maximum Product Length
Maximum Product Length - (Only active in Auto Glue) Determines the
maximum pattern length in Auto Glue Mode. If this is set to “0” the function is
disabled.