Installation instructions geoTHERM VWS/VWW 0020051574_01
58
Display shown
Description
Factory setting
Holiday programming
6
for cpl. System
Period of time
1 > 06.01.08
08.01.08
2
14.01.08
30.01.08
Room Temp. setpoint
12 °C
> Set start day
For the controller and its connected system compo-
nents it is possible to programme two holiday peri-
ods with the introduction of the date. Moreover, the
desired target room temperature can be set for holi-
days, i.e. regardless of the preset timer programme.
After the holiday time has elapsed, the controller au-
tomatically goes back to the previously selected op-
erating mode. The holiday program can be activated
only in auto and eco operating mode.
Connected cylinder charging circuits or circulation
pump circuits are automatically switched to OFF op-
erating mode during the holiday time program.
Period 1:
01.01.2003 -
01.01.2003
Period 2:
01.01.2003 -
01.01.2003
Room Temp.
setpoint 15 °C
Basic data
7
Date
21.04.08
Day of
week
Mo
Time
09:35
> Settable values
In the
Basic data
menu, you can set the current
date
, the
day of the week
and, if no DCF radio re-
ception is possible, the current
time
for the control-
ler.
These settings apply to all connected system compo-
nents.
Code layer
8
Code number:
> 0 0 0 0
Standard code:
1 0 0 0
> Set figures
To access the
Code layer
(Technician level), enter
the appropriate Code (standard code 1000) and
press the right hand dial.
To view set values without entering the code, you
must press the dial once. You can then view all pa-
rameters of the code level by turning
the dial but not change them.
Security function:
Your code entry is reset again
15 minutes after your last change in the Code level
(actuation of one of the dials). To gain entry to the
Code level again after that, you will have to enter
the code once more.
1000
Table 8.3 Settable parameters in the operator level (contd.)
8 Controller