Installation instructions geoTHERM VWS/VWW 0020051574_01
16
4.7
Check the scope of delivery
AB
B
A1
2-
30
-0
1
AB
B
A
12
-3
0-0
1
L3
L2
L1
N
PE
L3
L2
L1
N
PE
L3
L2
L1
N
PE
L3
L3
L2
L1
N
N
PE
L3
L2
L1
S
S
N
PE
L2
L1
L3
N
AB
B
A8
-3
0-
01
AB
B
A
8-
30
-0
1
AB
B
A8
-3
0-
01
1
L
L
L
L
L
1
L
N
N
N
N
N
2
N
2
1
2
1
L
N
2
3
4
5
SC
H
6
7
8
AS
B
N
N
Au
f
Zu
L
N
1
2
1
2
1
2
1
2
1
2
1
2
DC
F OT
AF
-
+
Au
f
Zu
ZH
N
L
ZP
N
L SK
2-
P
N
L
HK
2-
P
HK
2
VF
2
RF
1
VF
1
SP
BU
S
DC
F/A
F
EV
U
1x
ZP
LP
/U
V
1
AB
B
A1
2-
30
-0
1
3
2
1
6
5
4
7
8
9
10
11
12
Fig. 4.5 Checking the supplied material
For key, see Table 4.2.
The heat pump is supplied in four packing units.
h
Note
Before installing the heat pump, the in-
staller must perform a visual inspection
for possible transport damage.
• Check the heat pump and the separately packaged op-
erating console for any transport damage.
Pos.
Amount
Description
1
1
Heat pump
2
2
Side cladding panels
3
1
Operating console, pillar cover
4
1
6 litre brine expansion tank, max. 3 bar, fixing
material
5
1
VRC-DCF outside temperature sensor
6
4
VR 10 sensors
7
1
Control cable for vrnetDIALOG
8
4
Flexible connecting hoses (600 mm long, with
1 1/2" internal thread fitted on heating/heat
source side)
9
1
Expansion relief valve for brine circuit, 1/2",
3 bar
10
4
Installation instructions, operating manual
11
8
2
4
2
2
Seals for heating circuit connecting hoses (grey)
and heat source circuit (yellow/green)
M6 flat-headed screws for fitting the operating
console to the frame (plus one spare screw)
Flat-headed screws for fixing side cladding to
frame
Self-tapping screws for the operating console
frame (incl. one spare screw)
Self-tapping screws for fastening the vrnetDIA-
LOG unit
12
4
Front and rear cladding panels
Table 4.2 Scope of delivery
The frame for the operating console is already fastened
to the heat pump casing on delivery.
4.8
Transporting the heat pump
• Carefully remove the packaging and padding, taking
care not to damage any parts of the unit.
d
Danger!
Risk of injury!
The heat pump is too heavy to be lifted
by persons during transportation. You
should therefore only use one of the
specified transportation methods.
a
Caution!
Risk of damage!
Regardless of the mode of transport, the
heat pump must never be tilted by more
than 45°. Otherwise it can cause mal-
functions in the coolant circuit during
later operation, which in the worst case
can lead to a failure of the whole sys-
tem.
The heat pump may only be transported using the fol-
lowing methods (see Fig. 4.6):
- Forklift truck
- Lifting trolley
4 Assembly and installation