Installation instructions geoTHERM VWS/VWW 0020051574_01
6.6.6 Mixer circuit with buffer cylinder, domestic
hot water cylinder and external passive
cooling (hydraulic plan 10)
a
Caution!
Risk of damage!
The electrical auxiliary heating must be
protected on the customer side by a non
self-resetting thermal cut-out that pro-
vides all-pole disconnection.
h
Note
Hydraulic plan 10 is only suitable for
geoTHERM VWS x 0/2 (brine water).
The dimensioning of the cooling heat ex-
changer and brine mixer valve must be
carried out on the customer side.
Fig. 6.12 Hydraulic plan 10
The regulated underfloor heating circuits are operated
by the external heating circuit pump from the buffer
cylinder via a mixer. Flow temperature sensor VF2 is in-
stalled downstream of the diverter valve in the heating
flow (necessary for cooling function).
The heat pump responds to a demand for heat from the
buffer cylinder.
The brine pump is only included with VWS.