Control unit
vacon • 47
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
5
5.3.2
Standard I/O terminals
The terminals of the
Standard I/O
and the
Relays
are described below. For more information on con-
nections, see chapter 7.3.1.
The terminals shown on shadowed background are assigned for signals with optional functions se-
lectable with DIP switches. For more information, see chapter 5.3.7.
Table 21. Control I/O terminal signals and connection example.
Standard I/O terminals
Terminal
Signal
A
RS485_A
Serial bus, negative
B
RS485_B
Serial bus, positive
1
+10 Vref
Reference output
2
AI1+
Analogue input,
voltage or current
3
GND
I/O signal ground
6
24Vout
24V aux. voltage
7
DIN COM
Digital inputs com-
mon
8
DI1
Digital input 1
9
DI2
Digital input 2
10
DI3
Digital input 3
4
AI2+
Analogue input,
voltage or current
5
GND
I/O signal ground
13
DO1-
Digital output 1 com-
mon
14
DI4
Digital input 4
15
DI5
Digital input 5
16
DI6
Digital input 6
18
AO1+
Analogue signal
(+output)
20
DO1+
Digital output 1
V
X1
Remote reference
4...20mA/0...10V
Reference potentiometer
1...10k
Ω