Table 27. Power ratings of
VACON
®
20 X, supply voltage 208-240V.
Mains Voltage 3AC 208-240V, 50/60 Hz
AC drive
type
Input
current
[A]
Loadability
Motor shaft power
230V
240V
Rated continuous
current IN
[A]
50% overload
current
[A]
Max current
IS
[kW]
[HP]
MU2
0004
4.3
3.7
5.6
7.4
0.75
1.0
0005
6.8
4.8
7.2
9.6
1.1
1.5
0007
8.4
7.0
10.5
14.0
1.5
2.0
MU3
0011
13.4
11.0
16.5
22.0
2.2
3.0
0012
14.2
12.5
18.8
25.0
3.0
4.0
0017
20.6
17.5
26.3
35.0
4.0
5.0
Table 28. Power ratings of
VACON
®
20 X, supply voltage 1AC 208-240V.
Mains Voltage 1AC 208-240V, 50/60 Hz
AC drive
type
Input
current
[A]
Loadability
Motor shaft power
230V
230V
Rated continuous
current IN
[A]
50% overload
current
[A]
Max current
IS
[kW]
[HP]
MU2
0004
8.3
3.7
5.6
7.4
0.75
1.0
0005
11.2
4.8
7.2
9.6
1.1
1.5
0007
14.1
7.0
10.5
14.0
1.5
2.0