2NM/2NX/2NY/2NZ/2P0/2P6
1-5-70
32. Stand the main unit front side up.
33. Remove four screws each and then
remove the bottom plate 1 and the bot-
tom plate 2.
Figure 1-5-119
(50/60 ppm model only)
(1)Release two hooks and then remove the
wire cover.
(2)Pull the connector of lift sensor out.
Figure 1-5-120
Screw
Screw
Screw
Screw
Screw
Botom plate 2
Screw
Screw
Screw
Bottom plate 1
Lift sensor
Hooks
Connector
Wire cover