2NM/2NX/2NY/2NZ/2P0/2P6
1-4-34
6020
Abnormally high fuser
thermistor 2 temperature
(Center)
(50/60 ppm model only)
Fuser thermistor 2 detects a
temperature higher than
235°C/455°F.
In a heater-off state, the
detection temperature of fuser
thermistor 2 is higher than
195°C/383°F after the detec-
tion temperature of fuser
thermistor 2 was 155°C/311°F
or less.
Fuser unit
1. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Fuser unit and fuser thermistor connect
PWB (YC2)
Fuser thermistor connect PWB and con-
trol PWB (YC21)
2. If the wiring is disconnected, shorted or
grounded, replace the wiring.
3. Replace the Fuser unit (see page 1-5-
Fuser thermistor
connect PWB
Replace the fuser thermistor connect PWB.
Control PWB
1. Check the control software and upgrade
to the latest, if necessary.
2. Replace the control PWB and check for
correct operation (see page 2-2-12).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for P-4030 MFP
Page 7: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Page 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Page 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Page 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Page 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...